A blinded evaluation published in the International Journal of Clinical Pharmacy found that ChatGPT produced patient leaflets for oral anticoagulants scoring as high as official FDA Medication Guides on informational quality, with both reaching a median modified DISCERN score of 41 out of 65. Gemini and DeepSeek scored significantly lower, at 33 and 34 respectively. The study, led by Mohammed Amer Khan and reported by Bioengineer.org, also found that every source tested — the AI models and the federal guides alike — showed shortfalls in practical actionability and linguistic accessibility.
That last finding is the one that matters most. Anticoagulants are a drug class where a misunderstanding can be fatal: patients must grasp daily dosing, missed-dose management, dietary interactions, and the subtle signs of internal bleeding. A study showing that the benchmark materials themselves struggle on actionability says less about AI than it does about the patient-education standard the industry has been working from.
The comparison was built to be fair to the machines. Researchers tested five major oral anticoagulants — warfarin, apixaban, dabigatran, rivaroxaban, and edoxaban — against the FDA-approved guides for Coumadin, Eliquis, Pradaxa, Xarelto, and Savaysa. Three publicly accessible models were used in their default web interfaces in April 2026: ChatGPT (OpenAI, GPT-5.4), Gemini (Google DeepMind, 2.5 Pro), and DeepSeek (DeepSeek AI, V3). Brand names were stripped and replaced with generic chemical equivalents, and all prompts used a zero-shot framework based directly on federal labelling templates, covering nine pharmacological domains from indications to storage. Readers following this should also see FDA Approves Shionogi's Xocova as First Oral COVID-19 Post-Exposure Prophylaxis.
How was the study scored?
Three independent clinical pharmacists, each with at least five years of specialised anticoagulation experience, scored blinded and anonymised leaflets on two standardised instruments. The PEMAT-P tool measures understandability — how readily patients process the concepts — and actionability, meaning whether readers can identify and execute concrete health steps. The modified DISCERN instrument rates overall informational quality on a 65-point scale, with citation criteria excluded because federal guides carry no academic references. The team also ran seven readability indices and checked output reproducibility across repeated generations within a day and over a 28-day window.
What did the scores actually show?
On the modified DISCERN scale, ChatGPT and the FDA materials tied at a median of 41. DeepSeek reached 34 and Gemini 33. Post hoc testing confirmed ChatGPT scored significantly higher than both rival models, and the FDA guides also beat Gemini, while no significant difference separated ChatGPT from the regulatory materials. The gap for DeepSeek and Gemini came from failing to convey treatment uncertainties, clarify the purpose of the information, present balanced therapeutic risks, or support shared decision-making.
Understandability results were more forgiving. Every source cleared the established 70 percent acceptability threshold on PEMAT-P. ChatGPT led at a median of 91.6 percent, followed by the FDA materials at 83.3 percent, with DeepSeek and Gemini each at 75 percent. But the pairwise differences did not hold up after Bonferroni adjustment — a statistical correction that lowers the chance of false positives when many comparisons are run. In plain terms: the understandability ranking looks like a hierarchy, but the study could not confirm one. We covered a connected angle in FDA's Expedited IND Comment Window Nears Close After Gene Therapy Holds.
| Source | Median modified DISCERN (of 65) | Median PEMAT-P understandability |
|---|---|---|
| ChatGPT (GPT-5.4) | 41 | 91.6% |
| FDA Medication Guides | 41 | 83.3% |
| DeepSeek (V3) | 34 | 75% |
| Gemini (2.5 Pro) | 33 | 75% |
Why the actionability gap is the real story
The investigators framed the problem bluntly: synthetic health materials require independent professional review and must not operate as standalone educational tools. That caution applies to a class of drugs where preventable hospitalisations from anticoagulation mismanagement are a routine feature of clinical practice. Generative AI tools carry no formal clinical oversight or standardised quality assurance, and experts have raised concerns about factual omissions, linguistic instability, and medical hallucinations with life-threatening consequences.
But the study's comparator arm undercuts any easy reading that regulation solves this. FDA-approved medication guides have historically exceeded recommended public reading-comprehension thresholds, per the study's account. When the regulated benchmark and the unregulated challenger tie on quality and both miss on actionability, the deficit looks systemic to how patient leaflets are written — not a defect unique to machine-generated text. Patients are already turning to public large language models for accessible self-care guidance, which is precisely the demand the current guides fail to meet.
What this study does not settle
The evaluation covered one drug class, three models at a single point in time, and scoring by a three-pharmacist panel. Model versions change quickly — GPT-5.4, Gemini 2.5 Pro, and DeepSeek V3 are snapshots from April 2026 — so any ranking is perishable. The reproducibility testing across 28 days addresses output stability, but the retrieved reporting does not detail those results. And because the source text is truncated before the full actionability figures, the exact PEMAT-P actionability subscale scores for each source are not available here; the study's stated conclusion is that all sources, AI and federal alike, showed consistent shortfalls on that measure.
The practical implication for device makers, health systems, and anyone producing patient-facing material is that informational quality is a solved-enough problem to stop being the headline. The open question — for regulators and for AI developers — is whether materials can be built and reviewed so patients can act on them, not just understand them.